ZX-E
Capteur de mesure inductif intelligent
ZX-E est la meilleure solution pour une mesure précise des objets métalliques. Il est fortement recommandé dans les milieux difficiles tels que l'automobile et les machines de traitement des métaux.
- Résolution élevée de 1 µm
- Temps de réponse ultrarapide de 150 µs
- Remplacement facile des têtes de capteurs
- Concept de plateforme modulaire pour les différentes technologies de détection
- Simplicité de l'ajustement de linéarité pour tout métal
Caractéristiques et références
Ordering information
Sensors
Sensor heads
Resolution1 |
||||
---|---|---|---|---|
ZX-ED01T2 |
||||
ZX-ED02T2 |
||||
ZX-EM02T2 |
||||
ZX-EM07MT2 |
||||
ZX-EM02HT4 |
Amplifier units
Note: Compatible connection with the sensor head.
Accessories (order separately)
Calculating unit
Amplifier mounting brackets
SmartMonitor sensor setup tool for Personal Computer connection
ZX-SFW11EV35 |
|
Cables with connectors on both ends (for extension)*
* Robot cable models are also available. The model numbers are ZX-XC_R.
Specifications
Sensor heads
Magnetic metals |
||||||||
Resolution6 |
||||||||
Linearity7 |
±1% F.S.8 |
|||||||
Temperature characteristic9 |
||||||||
Operating10 |
||||||||
Storage5 |
||||||||
1,000 VAC, 50/60 Hz for 1 min between charged parts and case |
||||||||
10 to 55 Hz with 1.5-mm double amplitude for 2 h each in X, Y, and Z directions |
||||||||
IEC60529, IP6011 |
||||||||
Amplifier units
Possible average count settings12 |
1, 2, 4, 8, 16, 32, 64, 128, 256, 512, 1,024, 2,048, or 4,096 |
|
Linear output13 |
Current output: 4 to 20 mA/F.S., max. load resistance: 300 Ω Voltage output: ±4 V (±5 V, 1 to 5 V 14), output impedance: 100 Ω |
|
NPN open-collector outputs, 30 VDC, 50 mA max. |
PNP open-collector outputs, 30 VDC, 50 mA max. |
|
Zero reset input, timing input, reset input, judgement output hold input |
ON: Supply voltage short-circuited or supply voltage within 1.5 V |
|
|
||
Judgement indicators: High (orange), pass (green), low (yellow), 7-segment main digital display (red), |
||
0.5% F.S. of linear output value at ±20% of power supply voltage |
||
140 mA max. with power supply voltage of 24 VDC (with sensor connected) |
||
Operating and storage: 0 to 50°C (with no icing or condensation) |
||
10 to 150 Hz with 0.7-mm double amplitude for 80 min each in X, Y, and Z directions |
||
300 m/s2, 3 times each in 6 directions (up, down, left, right, forward, backward) |
||
Case: PBT (polybutylene terephthalate), cover: Polycarbonate |
||
2. Models with protective spiral tubes are also available. Add a suffix of “-S” to the above model numbers when ordering. (Example: ZX-ED01T-S)
6.
Accuracy: The resolution is the deviation (
±3
σ) in the linear output when connected to the ZX-EDA amplifier unit. The above values indicate the deviations observed 30 minutes after the power is turned ON.
(The resolution is measured with Omron's standard reference object at ½ of the measurement range with the ZX-EDA set for the maximum average count of 4,096 per period.)
The resolution is given at the repeat accuracy for a stationary workpiece, and is not an indication of the distance accuracy. The resolution may be adversely affected under strong electromagnetic fields.
7. Linearity: The linearity is given as the error in an ideal straight line displacement output when measuring the standard reference object. The linearity and measurement values vary with the object being measured.
9. Temperature characteristic: The temperature characteristic is measured with Omron's standard reference object at ½ of the measurement range.
12.
The response speed of the linear output is calculated as the measurement period x (average count setting + 1) (with fixed sensitivity).
The response speed of the judgement outputs is calculated as the measurement period x (average count setting + 1) (with fixed sensitivity).
2. Models with protective spiral tubes are also available. Add a suffix of “-S” to the above model numbers when ordering. (Example: ZX-ED01T-S)
6.
Accuracy: The resolution is the deviation (
±3
σ) in the linear output when connected to the ZX-EDA amplifier unit. The above values indicate the deviations observed 30 minutes after the power is turned ON.
(The resolution is measured with Omron's standard reference object at ½ of the measurement range with the ZX-EDA set for the maximum average count of 4,096 per period.)
The resolution is given at the repeat accuracy for a stationary workpiece, and is not an indication of the distance accuracy. The resolution may be adversely affected under strong electromagnetic fields.
7. Linearity: The linearity is given as the error in an ideal straight line displacement output when measuring the standard reference object. The linearity and measurement values vary with the object being measured.
9. Temperature characteristic: The temperature characteristic is measured with Omron's standard reference object at ½ of the measurement range.
12.
The response speed of the linear output is calculated as the measurement period x (average count setting + 1) (with fixed sensitivity).
The response speed of the judgement outputs is calculated as the measurement period x (average count setting + 1) (with fixed sensitivity).
En quoi pouvons-nous vous aider ?
Pour toute question ou demande de devis, veuillez nous contacter ou envoyer une demande.
Contactez-moi ZX-E
Merci de votre demande. Nous reviendrons vers vous dès que possible.
Nous rencontrons des problèmes techniques. Votre demande ne peut être traitée. Veuillez nous excuser et ré-essayer plus tard. Détails :
DownloadDevis pour ZX-E
Vous pouvez utiliser ce formulaire pour demander un devis sur le produit de votre choix. Merci de compléter tous les champs *. Les informations sont traitées de manière confidentielle.
Merci de votre demande. Nous vous enverrons l'information demandée au plus tôt.
Nous rencontrons des problèmes techniques. Votre demande ne peut être traitée. Veuillez nous excuser et ré-essayer plus tard. Détails :
Download