E3NX-FA
- Bibliothèque CAO
- E3NX-FA Datasheet
Thank you for downloading the E3NX-FA Datasheet
Download againDid you know that 4 out of 5 distributors buy this product in a bundle?
There are many variations of passages of Lorem Ipsum available, but the majority have suffered alteration in some form, by injected humour, or randomised words which don't look even slightly believable.

Amplificateur à fibre numérique hautes performances
L'E3NX-FA est l’amplificateur idéal pour les applications de fibre standard destinées à la détection à longue distance des petits objets ou aux processus grande vitesse.
- Apprentissage aisé en quelques minutes grâce au réglage intelligent
- La nouvelle technologie N-Smart améliore considérablement les performances en matière de détection longue distance, de détection minimale de taille d’objet et de vitesse
- Consultez facilement les informations relatives à l'état du capteur en toute transparence grâce aux fonctions Solution Viewer et Change Finder
- Unité de communication EtherCAT pour la connectivité haut débit de bus de terrain
N-Smart technology
Le dispositif de couplage GIGA RAY 2S haute efficacité permet d'obtenir un signal clair et une large plage dynamique. Ses fonctionnalités sont complétées par le nouvel algorithme de réception léger « Smart Noise Reduction » (réduction de bruit intelligente) et l'IC « N-Core » grande vitesse et haute précision. Combinées, ces trois technologies permettent d'améliorer les performances de base de l'E3NX-FA et de réduire le rapport signal/bruit, 2,5 fois meilleur que sur les modèles classiques.

Dynamic Power Control
Le contrôle dynamique de la puissance permet de compenser automatiquement les différences de niveau incident causées par la poussière ou les vibrations. En outre, un signal de sortie d'alarme est envoyé à des fins de maintenance prédictive si le capteur atteint la limite de compensation.

Timer functions
Permet de régler la portée et la temporisation du signal de sortie :
- T1 : temporisation à la fermeture
- T2 : temporisation à l'ouverture
- Il est possible de régler séparément les fonctions T1 et T2.

Ordering information
Fiber Amplifier Units
E3NX-FA11-5 2M1 |
||||
Model for Sensor Communications Unit2 |
||||
Accessories (Sold Separately)
Fiber amplifier connectors
![]() |
|||||
Communication units
![]() |
||
![]() |
E3NW-CRT3 |
|
Distributed Sensor Unit4 |
![]() |
Note: Refer to your OMRON website for details.
Specifications
Standard models/ Advanced models/ Infrared models
E3NX-FA11-5 5 |
|||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|
Power supply reverse polarity protection, output short-circuit protection, and output reverse polarity protection |
|||||||||||
Operate or reset for model with 1 output: 30 µs (Super High Speed mode (SHS2) of E3NX-FA11-5 is 60 µs each), with 2 outputs: 32 µs |
|||||||||||
Smart Tuning (2-point tuning, full auto tuning, position tuning, maximum sensitivity tuning, power tuning, or percentage tuning (−99% to 99%)) or manual adjustment |
|||||||||||
No. of Units for mutual interference prevention6 |
2 units when the detection mode is set to Super High Speed mode (SHS2), and for other models, the mutual interference prevention function is disabled. |
||||||||||
Automatic power control (APC), Dynamic power control (DPC), Timer, Zero reset, Resetting settings, Eco mode, Bank switching, Power tuning |
Analog output models/Model for Sensor Communications Unit
− 7 |
− 1 |
|||
Supplied from the connector through the communication units. |
||||
Load power supply voltage: (depends on the NPN/PNP output format)
Load current:
(Residual voltage: |
||||
Voltage output: 1-5 VDC (10 kΩ or more connected load), temperature characteristics: |
||||
Smart Tuning (2-point tuning, full auto tuning, position tuning, maximum sensitivity tuning, power tuning, percentage tuning (-99% to 99%)) or manual adjustment |
||||
With E3NW-ECT: 30 units (When connected to an OMRON NJ-series Controller.) With E3NW-CRT: 16 units (Note: E3NX-FAH0 can not be connected.) |
||||
No. of Units for mutual interference prevention8 |
0 (The mutual interference prevention function is disabled if the detection mode is set to super-high-speed mode.) |
|||
Automatic power control (APC), Dynamic power control (DPC), Timer, Zero reset, Resetting settings, Eco mode, Bank switching, Power tuning |
Easy One-Button-Teaching/Smart Tuning

Easy setting of optimum power and threshold by pushing tune button twice.
Smart power control

Enhanced signal stability control for compensating power reductions caused by temperature drift, dust or aging of LED. Alarm output added for predictive maintenance.
N-Smart platform

The N-Smart platform provides wide portfolio of advanced sensors − all with the same intuitive operation concept and field bus connectivity.


Brochures
Afficher tout brochuresCatalogues
Afficher tout cataloguesGuide de connexion
Fichiers de descriptions de produits
Afficher tout fichiers de descriptions de produitsDatasheets
Afficher tout datasheetsManuels
S'abonner aux mises à jour du produit
Newsletters sur les innovations produit, les solutions et les services, directement dans votre boîte de réception.
Merci pour votre abonnement à eNews d'Omron. Vous recevrez prochainement un e-mail de confirmation de notre part, contenant un lien qui activera votre abonnement. Cette méthode permet d'observer les dispositions légales et de nous assurer que personne n'utilisera à tort votre adresse e-mail.
Nous rencontrons des problèmes techniques. Votre demande ne peut être traitée. Veuillez nous excuser et ré-essayer plus tard. Détails :
DownloadDocumentation du produit
Téléchargez des fiches techniques, des manuels et des brochures.
Parcourir le centre de téléchargementCours de formation
Bénéficiez de la formation de nos meilleurs ingénieurs. Niveau débutant à avancé.
Afficher les cours de formation