G9SE

Fonctions

Blocs logiques de sécurité compacts

La série G9SE est conçue pour le contrôle d'arrêt d'urgence, des portes et de sécurité. Les modules avec deux ou quatre contacts de sécurité et temporisation à la mise hors tension sont disponibles dans des boîtiers compacts.

  • Simple câblage sur panneau avant à l'aide de bornes enfichables.
  • Largeur de 17,5 ou 22,5 mm pour un espace réduit
  • Temps de réponse max. 15 ms
  • Temporisation mise hors tension sécurisée PLe
  • Conforme aux normes EN 81-1, EN 81-2
  • Répond aux niveaux PLe (EN ISO 13849-1) et SIL 3 (EN 61508)
Caractéristiques et références

Ordering information

Safety outputs

Auxiliary outputs 1

Max. OFF-delay time 2

Rated voltage

Order code

Instantaneous

OFF-delayed

DPST-NO

-

1 PNP transistor output

-

24 VDC

G9SE-201

4PST-NO

G9SE-401

DPST-NO

DPST-NO

5 s

G9SE-221-T05

DPST-NO

DPST-NO

30 s

G9SE-221-T30

Specifications

Ratings

Power Input

Item

G9SE-201

G9SE-401

G9SE-221-T _

Rated supply voltage

24 VDC

Operating voltage range

-15% to 10% of rated supply voltage

Rated power consumption3

3 W max.

4 W max.

 

Outputs

Item

G9SE-201

G9SE-401

G9SE-221-T _

Safety output

OFF-delayed safety output

Contact output

250 VAC 5 A 30 VDC 5 A (resistance load)

Auxiliary output

PNP transistor output Load current: 100 mA DC max.

 

Characteristics

Item

G9SE-201

G9SE-401

G9SE-221-T _

Operating time (OFF to ON state) 4

100 ms Max. 5

Response time (ON to OFF state) 6

15 ms Max.

Inputs

Input current

5 mA Min.

ON voltage

11 VDC Min.

OFF voltage

5 VDC Max.

OFF current

1 mA Max.

Maximum cable length

100 m Max.

Reset input time

250 ms Min.

Contact outputs

Contact resistance 7

100 m Ω

Mechanical durability

5,000,000 operations Min.

Electrical durability

50,000 operations Min.

Switching specification Inductive load

(IEC/EN60947-5-1)

AC15: 240 VAC 2 A

DC13: 24 VDC 1.5 A

Minimum applicable load

24 VDC 4 mA

Conditional short-circuit current

(IEC/EN60947-5-1)

100A 8

Surrounding air temperature

-10 to 55 ° C (No freezing or condensation)


1. PNP transistor output

2. The OFF-delay time can be set in 16 steps as follows:
T05: 0/0.1/0.2/0.3/0.4/0.5/0.6/0.7/0.8/1/1.5/2/2.5/3/4/5 s
T30: 0/1/2/4/5/6/7/8/9/10/12/14/16/20/25/30 s

3. Power consumption of loads not included.

4. The operating time is the time it takes for the safety contact to close after the safety inputs and feedback-reset input are turned ON. Not including bounce time.

5. This is in normal operation. When executing non-regular self-diagnosis for Safety output circuit, G9SE operating time become 500 ms max..

6. The response time is the time it takes for the safety main contact to open after the safety input is turned OFF. Includes bouncetime.

7. This is initial value using the voltage-drop method with 1 A at 5 VDC.

8. Use an 8 A fuse that conforms to IEC 60127 as a short-circuit protection device. This fuse is not included with the G9SE.

1. PNP transistor output

2. The OFF-delay time can be set in 16 steps as follows:
T05: 0/0.1/0.2/0.3/0.4/0.5/0.6/0.7/0.8/1/1.5/2/2.5/3/4/5 s
T30: 0/1/2/4/5/6/7/8/9/10/12/14/16/20/25/30 s

3. Power consumption of loads not included.

4. The operating time is the time it takes for the safety contact to close after the safety inputs and feedback-reset input are turned ON. Not including bounce time.

5. This is in normal operation. When executing non-regular self-diagnosis for Safety output circuit, G9SE operating time become 500 ms max..

6. The response time is the time it takes for the safety main contact to open after the safety input is turned OFF. Includes bouncetime.

7. This is initial value using the voltage-drop method with 1 A at 5 VDC.

8. Use an 8 A fuse that conforms to IEC 60127 as a short-circuit protection device. This fuse is not included with the G9SE.

Vous avez une question ?

Nous sommes prêts à vous aider.

Contactez-nous.

S'abonner aux mises à jour du produit

Newsletters sur les innovations produit, les solutions et les services, directement dans votre boîte de réception.

Merci pour votre abonnement à eNews d'Omron. Vous recevrez prochainement un e-mail de confirmation de notre part, contenant un lien qui activera votre abonnement. Cette méthode permet d'observer les dispositions légales et de nous assurer que personne n'utilisera à tort votre adresse e-mail.

Nous rencontrons des problèmes techniques. Votre demande ne peut être traitée. Veuillez nous excuser et ré-essayer plus tard. Détails :

Download

Documentation du produit

Téléchargez des fiches techniques, des manuels et des brochures.

Parcourir le centre de téléchargement

Cours de formation

Bénéficiez de la formation de nos meilleurs ingénieurs. Niveau débutant à avancé.

Afficher les cours de formation