KM-N2
- Bibliothèque CAO
- KM-N2 / KM-N3 Power Monitors Datasheet
Thank you for downloading the KM-N2 / KM-N3 Power Monitors Datasheet
Download againDid you know that 4 out of 5 distributors buy this product in a bundle?
There are many variations of passages of Lorem Ipsum available, but the majority have suffered alteration in some form, by injected humour, or randomised words which don't look even slightly believable.

Moniteur d’alimentation global pour le montage de panneaux de contrôle à l’intérieur
- Résolution des problèmes de conception, d’installation et de mise en service.
- Possibilité de mesurer jusqu’à quatre circuits à l’aide d’un seul moniteur d’alimentation.
- Utilisation de TC à usage général et gestion d’une variété de chantiers.
- Écran LCD large et facile à lire pour une meilleure visibilité.
- Mesures de haute précision IEC de classe 0.5S (moniteur d’alimentation uniquement).
Ordering information
Power monitor
Note: To use a commercially available current transformer, use a CT with a secondary current rating of 1 A or 5 A, and a rated load of at least 1.0 VA.
Connectable OMRON split-type Current Transformers (CTs)
Note: The CT cables connected to the CT have the following recommended characteristics:
- cross section 0.75 mm² = AWG18
- 2C (number of internal wires is two)
- 1 m long maximum.
The CT cables are not provided by Omron
Specifications
Ratings (Power monitor)
Single-phase two-wire, single-phase three-wire, three-phase three-wire, and three-phase four-wire |
||
Single-phase two-wire: 4 circuits max., Single-phase three-wire or three-phase three-wire: 2 circuits max., |
||
Single-phase, 2-wire:100 to 277 VAC |
||
General-purpose CT with a rated secondary current of 1 A or 5 A 1 |
||
Overvoltage category II, measurement category II, pollution degree 2 |
||
Industrial electromagnetic environment (EN/IEC 61326-1 Table 2) |
||
Ratings (Connectable OMRON Split-type Current Transformers (CTs))
100 MΩ min. (at 500 VDC) (Between through hole and output lead) |
|||
−20 to 55 °C, 85% max. relative humidity (with no condensation) |
|||
−30 to 90 °C, 85% max. relative humidity (with no condensation) |
Performance (Power monitor)
Total power consumption (active, regenerative, and reactive), power (active and reactive), current, voltage, power factor, and frequency |
||
0.5% (IEC 62053-22 class 0.5S) 2 |
||
2% (IEC 62053-23 class 2) 1 |
||
Single amplitude: 0.1 mm, Acceleration: 15 m/s2, Frequency: 10 to 150 Hz, 10 sweeps for 8 min each along three axes |
||
150 m/s², 3 times each in 6 directions (up/down, left/right, forward/backward) |
||
ON residual voltage: 1.5 V max. (for output current of 50 mA) |
||
If you measure more than one circuit with one Power Monitor, the number of circuits is treated as the number of connected Power Monitors. |
||
S'abonner aux mises à jour du produit
Newsletters sur les innovations produit, les solutions et les services, directement dans votre boîte de réception.
Merci pour votre abonnement à eNews d'Omron. Vous recevrez prochainement un e-mail de confirmation de notre part, contenant un lien qui activera votre abonnement. Cette méthode permet d'observer les dispositions légales et de nous assurer que personne n'utilisera à tort votre adresse e-mail.
Nous rencontrons des problèmes techniques. Votre demande ne peut être traitée. Veuillez nous excuser et ré-essayer plus tard. Détails :
DownloadDocumentation du produit
Téléchargez des fiches techniques, des manuels et des brochures.
Parcourir le centre de téléchargementCours de formation
Bénéficiez de la formation de nos meilleurs ingénieurs. Niveau débutant à avancé.
Afficher les cours de formation